CMP_DONE=0, WRITE_PROT_EN=0, CPU_LOW_VOLT=0, BUS_ERR=0, INVAL_BIT=0, RST_SRC=0
RTC Status Register
INVAL_BIT | Invalidate CPU read/write access bit. 0 (0): Time /Date Counters can be read/written. Time /Date is valid. 1 (1): Time /Date Counter values are changing or Time /Date is invalid and cannot be read or written. |
WRITE_PROT_EN | Write Protect Enable status bit. 0 (0): Registers are unlocked and can be accessed. 1 (1): Registers are locked and in read-only mode. |
CPU_LOW_VOLT | CPU Low Voltage Warning status bit. 0 (0): CPU in Normal Operating Voltage. 1 (1): CPU Voltage is below Normal Operating Voltage. RTC Registers in read-only mode. |
RST_SRC | Reset Source bit. 0 (0): Part was reset due to Standby Mode Exit (that is when VDD is powered up and VBAT was not powered down at all). 1 (1): Part was reset due to Power-On Reset (that is Power On Reset when both VBAT and VDD are powered up). |
CMP_INT | Compensation Interval bit. |
WE | Write Enable bits. 2 (10): Enable Write Protection - Registers are locked. |
BUS_ERR | Bus Error bit. 0 (0): Read and Write accesses are normal. 1 (1): Read or Write accesses occurred when INVAL_BIT was asserted. |
CMP_DONE | Compensation Done bit. 0 (0): Compensation busy or not enabled. 1 (1): Compensation completed. |